Skip to content
IWILL

Serial I/O

Industrial PCs with 4 or more COM ports

Native serial ports for PLCs, CNC controllers, meters, scales and legacy SCADA devices, without USB-to-serial adapters.

16 IWILL models. Every system below has at least four COM ports stated in its product data. Port types (RS-232, RS-422, RS-485), pin-5/9 power options and isolation vary by model and are confirmed on the datasheet and your quotation.

The range

Systems with 4+ COM ports

Box PCs and panel PCs, sorted by serial port count. Select a model for the full specification and downloads.

Systems with 4+ COM ports compared by processor, com ports, lan, fanless, operating temp.
ModelProcessorCOM portsLANFanlessOperating temp.
IWILL IBOX-708 Industrial PCsIBOX-7086th Gen6×3x GbE LANNot specifiedConfirmed on enquiry
IWILL IBOX-3126 Industrial PCsIBOX-312611th Gen6×3x 2.5G LANYesConfirmed on enquiry
IWILL IBOX-3326 Industrial PCsIBOX-3326J19006×2x GbE LANYesConfirmed on enquiry
ITPC-C10112th Gen6×2x GbE LANYes-20°C to 60°C
ITPC-C12112th Gen6×2x GbE LANYes-20°C to 60°C
ITPC-C15012th Gen6×2x GbE LANYes-20°C to 60°C
ITPC-C15612th Gen6×2x GbE LANYes-10°C to 60°C
ITPC-C17012th Gen6×2x GbE LANYes0°C to 50°C
ITPC-C21512th Gen6×2x GbE LANYes0°C to 50°C
IWILL IBOX-1026 Industrial PCsIBOX-1026J41255×2x GbE LANYesConfirmed on enquiry
IWILL IBOX-1326 Industrial PCsIBOX-1326N1005×2x GbE LANYesConfirmed on enquiry
IWILL IBOX-1426 Industrial PCsIBOX-1426J37105×2x GbE LANYesConfirmed on enquiry
IWILL IBOX-605 Industrial PCsIBOX-6058th Gen4×2x GbE LANYesConfirmed on enquiry
IWILL IBOX-1226 Industrial PCsIBOX-1226J64124×3x 2.5G LANYesConfirmed on enquiry
IWILL IBOX-3026 Industrial PCsIBOX-302611th Gen4×2x GbE LANYesConfirmed on enquiry
IWILL IBOX-3226 Industrial PCsIBOX-322612th Gen4×2x LANYesConfirmed on enquiry

“Not specified” means our product data does not state it; we confirm it on enquiry. Configuration options (processor variant, memory, storage) are agreed per order.

For OEMs

Building your own system? Boards with 4–10 COM ports

Industrial motherboards for OEM enclosures, kiosks and machine builders who need serial I/O on the board itself.

Building your own system? Boards with 4–10 COM ports
ModelProcessorCOM portsLAN
H-HSWS014th Gen10×2x GbE LAN
H-SKLS016th–7th Gen10×2x GbE LAN
H-ADLN02Alder Lake-N6×2x GbE LAN
H-ADLP0112th–13th Gen6×1x GbE LAN
H-EHL01J64126×1x GbE LAN
H-EHL03J64126×2x GbE LAN
H-HSWU014th–5th Gen6×2x GbE LAN
H-SKLS036th–7th Gen6×2x GbE LAN
IWILL H-SKLU01 Industrial MotherboardsH-SKLU016th–8th Gen6×2x GbE LAN
IWILL HI-J6412D26 Industrial MotherboardsHI-J6412D26J64126×2x GbE LAN
HM-1115D26i3-1115G46×2x GbE LAN
HM-N5095D16N50956×1x GbE LAN
HM-N5095D16-UHLN50956×1x GbE LAN
H-ADLN01Alder Lake-N4×1x GbE LAN
H-ADLN03Alder Lake-N4×2x GbE LAN
H-ADLP0212th–13th Gen4×1x GbE LAN

Why teams choose them

  • No adapters in the cabinet

    Native UARTs avoid the driver, latency and reliability problems that USB-to-serial dongles bring to 24/7 control systems.

  • RS-232 and RS-485 on one box

    Some models combine RS-232 ports with ports switchable to RS-485 (the C-series panel PCs, for example), so one PC can talk to a PLC, a meter bus and a barcode reader at once.

  • Fanless for dusty floors

    Sealed, fanless chassis with no intake to clog, suited to plant floors, pump stations and control cabinets.

  • Evaluate, then roll out

    Test one unit on your equipment, then order matched units with the same configuration for every line or site.

Frequently asked questions

Are the COM ports RS-232 or RS-485?

It depends on the model. Some combine plain RS-232 ports with ports that can be switched to RS-485; others list their COM ports without the split. The datasheet on each product page gives the detail, and we confirm the exact port types on your quotation.

Can I get more serial ports than listed?

Several platforms take COM expansion through internal headers or a mini-PCIe/M.2 serial card. Tell us how many ports and which standard you need and we will propose a configuration.

Do the ports support pin-9 power or isolation?

Powered COM (5 V / 12 V on pin 9) and isolated RS-485 are available on some models and boards only. Ask for them by name in your enquiry so we can confirm the exact model.

Which operating systems are supported?

Windows 10/11 and Linux are typical, and serial ports appear as standard COM / ttyS devices. Supported OS versions are listed per model.

Can you supply units for a multi-site rollout?

Yes. Evaluate one unit, then order matched units with the same BIOS and configuration for every site. Include quantities and delivery ZIP codes in your enquiry.

Tell us about your project

Share the devices you need to connect, the environment and the quantity. An engineer will recommend the model and configuration and send a written quotation. Authorized IWILL distributor for the United States; IWILL US is operated by Global Natural Imports LLC.

We store your analytics preference locally. Optional analytics loads only with your permission. See our Privacy Policy.