Skip to content
IWILL

Turnkey SCADA station

IBOX-3026 — a SCADA station that survives the floor

A fanless industrial computer built to run the supervisory layer: native COM ports for direct PLC communication, dual Intel LAN to separate the machine network from plant IT, and watchdog plus auto power-on for lights-out reliability.

4× COMModbus RTUi7 option
IWILL IBOX-3026 fanless SCADA station with native COM ports

The problem

Why a dedicated SCADA station?

Office PCs lack serial ports

Most current PCs have no RS-232/485, so PLCs and Modbus devices end up on USB adapters that drop links in the field.

Fans and plant dust do not mix

Dust and heat clog fans and shorten component life; a fanless chassis has no intake to block.

Branded HMI hardware adds cost

Proprietary operator panels and their runtime licenses add cost per seat.

Licensing that never ends

Commercial SCADA suites are often licensed per tag or per year. Open-source options fit many monitoring projects.

IBOX-3026 puts native COM ports, a -20°C to 60°C rating, and a standard x86 OS in one fanless box — run open-source SCADA or the commercial suite you already use.

Why this platform

Native COM ports

Real serial ports (RS-232/485) for Modbus RTU to PLCs, meters, and instruments — no USB-serial adapters that drop connection.

Dual Intel LAN

Physically separate the PLC/field network from the plant IT network at the hardware level.

Fanless, sealed

No fan to pull in conductive dust; solid-state construction rides out vibration.

Watchdog + auto power-on

Recovers from software hangs and returns after power loss, unattended.

Ports mapped to the plant

Native COM ports connect PLCs and field devices without USB adapters. RS-232 / RS-485 assignment per port is confirmed for each build.

  1. COM 1–2

    RS-232 console

    Direct serial links to PLCs, drives, and legacy instruments.

  2. COM 3–4

    RS-485 field bus

    Modbus RTU networks for meters, sensors, and remote I/O.

  3. LAN 1–2

    Plant and IT

    Modbus TCP, OPC UA, or MQTT on one port; a separate, segmented uplink on the other.

Key specifications

Processor
Intel 11th-gen Celeron to Core i7
Memory
1× DDR4, up to 32GB
Network
2× 1G LAN (Intel)
Serial
4× COM (RS-232/485)
Storage
M.2 2280 + 2.5" bay
Cooling
Fanless
All 8 specifications
Processor
Intel Celeron 6305E / i5-1135G7 / i7-1165G7 (11th Gen)
Memory
1x DDR4 2666/3200MHz, up to 32GB
Networking
2x 1000M LAN (Intel chipsets)
Serial ports
4x COM
Storage
1x M.2 2280 + 1x 2.5" HDD
I/O
2x USB 2.0, 6x USB 3.0, 1x HDMI, 1x VGA
Dimensions
230 × 166 × 68mm
Weight
2.2kg
Full product page

Software fit

  • Rapid SCADA
  • ScadaBR
  • Node-RED
  • Windows 10/11 IoT
  • Ubuntu / Debian

Software compatibility is validated for the exact model and release before quotation.

Open-source SCADA options

Both run on the IBOX-3026. Commercial suites run too — tell us which one you use.

FeatureRapid SCADAScadaBR
Platform.NET; Windows or LinuxJava web application
ProtocolsModbus RTU/TCP, OPC UA, MQTT via driversModbus RTU/TCP and others via data sources
Operator interfaceWeb HMI with desktop configuratorWeb HMI and editor
LicenseOpen sourceOpen source

Check each project’s current documentation for the drivers your equipment needs.

Own SCADA station vs the alternatives

The typical picture; individual products vary.

FeatureIBOX-3026Branded HMI panelOffice PC + USB adapters
Serial ports4× native COMVaries by modelUSB adapters
Recurring licenseNone required with open-source SCADARuntime license often requiredNone
CoolingFanlessVariesFan-cooled
Operating range-20°C to 60°CVariesOffice environment
Software choiceAny Windows or Linux SCADAVendor softwareAny

Where it fits

SCADA station

Run the HMI/historian and poll PLCs over Modbus RTU/TCP or OPC UA.

Line & machine control

A rugged operator station at the point of production.

Protocol gateway

Bridge legacy serial equipment onto the modern plant network.

Typical configurations

Starting points technical sales uses when sizing the IBOX-3026. Every build is confirmed against tag count, protocols, and HMI clients before quotation.

Monitoring

Pump stations and small plants

  • Celeron 6305E
  • 8GB DDR4
  • 256GB M.2 SSD
  • Linux with Rapid SCADA
Quote this configuration

Line HMI

Production lines with operator screens

  • Core i5-1135G7
  • 16GB DDR4
  • 512GB M.2 SSD
  • Windows or Linux, SCADA of your choice
Quote this configuration

Site server

Historian and multiple clients

  • Core i7-1165G7
  • 32GB DDR4
  • 1TB M.2 SSD + 2.5" bay
  • Historian database and OPC UA server
Quote this configuration

Frequently asked questions

Why native COM instead of USB adapters?

Onboard serial ports have stable device names and clean electrical behavior. USB-serial adapters are a leading cause of intermittent communication drops in the field.

Can it run open-source SCADA?

Yes — it is a standard x86 PC. Rapid SCADA, ScadaBR, and Node-RED all run well, alongside commercial suites. Confirm the OS image with your order.

How many Modbus devices can I connect?

Each RS-485 port runs its own Modbus RTU segment — typically up to 32 unit loads per segment, more with repeaters or low-load transceivers. Modbus TCP devices connect over the Gigabit LAN ports.

Does it support OPC UA?

OPC UA is a software feature: Rapid SCADA and most commercial suites include OPC UA client and server options, which the IBOX-3026 runs over its Gigabit LAN.

Is it rated for the cabinet environment?

Fanless construction and wide-temperature options by model suit cabinet installation. Send the ambient conditions for validation.

Related hardware

Ready to specify the IBOX-3026?

Send the configuration, quantity, application, and timing. Technical sales confirms compatibility, lead time, and pricing.

We store your analytics preference locally. Optional analytics loads only with your permission. See our Privacy Policy.